A fix for an ECU with broken fuel pump relay control Posted by walt [Email] (#2707) [Profile/Gallery]
(more from walt) on Thu, 5 Apr 2012 21:22:25
|
Had the common problem with LH 2.4 ECU (Bosch 0 280 000 580) in a 1990 C900 non/turbo not grounding the fuel pump relay coil to run fuel pump. Some people may replace ECU, repair ECU, use an 8-valve fuel pump relay, or simply run wire from ignition 15 circuit to fuel pump (which isn't safe after a collision which leaves driver unconscious and unable to switch off ignition). I opted for a relay control circuit found on a Volvo forum. Ran the fuel pump relay coil 85 terminal violet wire over to fuse/relay box and installed a fuel pump relay "missing pulse relay control" circuit as described in link below with a few modifications. Wire-wrapped it on a 1x1.5-inch circuit board, and epoxied it to the base of gutted generic auto relay, and installed it in vacant relay socket. Got ground, ignition supply (15-green/white), and ignition tachometer signal from EZK (blue) from the TSI socket in fuse/relay box. Now car is running more safely, because circuit turns off pump once engine stops running even if ignition switch stays in RUN position. Circuit also runs pump for 2 seconds when energized then turns pump off.
posted by 72.49.19...
missing pulse detector circuit for fuel pump control

, Thu, 5 Apr 2012 21:22:25 <-- Viewing This Message
No Site Registration is Required to Post - Site Membership is optional (Member Features List), but helps to keep the site online
for all Saabers. If the site helps you, please consider helping the site by becoming a member.
![]() |
![]() |
![]() |
![]() |
![]() |